¡@Charge Plate Monitor 

Charge Plate Monitor         
Charge Plate Monitor System is designed to provide quantitative measurements of the effectiveness of air ionization systems. The CPM employs a charge plate monitor design that utilizes an ultra-high impedance, high-voltage follower to monitor the test plate voltage. This technique provides very high accuracy and virtually infinite impedance loading of the plate, while allowing the test plate to be charged and monitored through the same small-diameter connection. The CPM has a serial interface port to connect with a computer to program test sequences, save, or retrieve test results. The CPM features two modes of operation, a discharge time mode with easy-to-program start and stop voltages, and a plate voltage mode.
Specification:
Size (W x H x D) 3.25" H x 12.5" W x 11" D
Weight 4.4 lb (2 kg)
Power Requirements All nominal line voltages or rechargeable battery (included)
Meter Range 0 to ¡Ó1100 V DC or peak AC
Display 4-digit red LED
Accuracy Better than 0.1% of full scale
Plate Capacitance to Ground 20 pF =/-2 pF
 
 
 
Charge Plate Monitor Products and Accessories
Description Part Number
Charge Plate Monitor, with 6"x 6" test plate & software 4008743

Back

¡@

¡@